• Laboratory & Industrial Quartz & Borosilicate Glasswares

Technical Data

Trace Impurities

Element (PPM) GE Type 214 Electric Fused Tubing & Rod (PPM) Max. GE Type 124 Electric Fused Ingot (PPM) Max. Heraeus Type TSC-3 Flame Fused Ingot (PPM) Corning HPFS 7980 Fused Silica Flame Fused Ingot (PPB)
Ag - - - <2
Al 19.0 19.0 15 <25
As <0.002 <0.002 - <15
Au - - - <1
B <0.2 <0.2 - <10
Ba - - - <1
Be - - - <0.5
Bi - - - <1
Ca 2.0 2.0 0.4 <15
Cd - - - <0.3
Co - - - <0.5
Cr - - <0.01 <1
Cu 0.1 0.1 <0.01 <2
Fe 0.8 0.8 0.05 <20
Ga - - - <0.5
K 3.0 3.0 0.2 <5
Li 2.0 2.0 0.2 <7.2
Mg 1.0 1.0 <0.01 <5
Mn 0.24 0.24 <0.01 <1
Mo - - - <1
Na 2.5 2.5 0.3 <187
Nd - - - -
Ni - - - <5
P - - - <50
Sb - - - <0.5
Sr - - - <0.5
Th - - - <0.5
Ti 2.0 2.0 1.1 <10
U - - - <1
V - - - <1
Y - - - -
Zn - - - <5
Zr 3.0 3.5 0.8 <5
OH Typical <5 Typical <5 170 <1000 PPM